← All tradesPrint / PDF
Waterproofer
Scope of Works — 32a Archbold Road, Roseville NSW 2069
3
Tasks
3
Rooms
2
Phases
0%
Complete
Not Started: 3
Phase Coverage
Pre-Con
Design
Approvals
Demo
Build
Finishes
External
Summary by Room
| Room | Tasks | Done | Phases |
|---|---|---|---|
| Ground Floor Bathroom | 1 | 0 | Pre-Con |
| Upstairs Bathroom | 1 | 0 | Pre-Con |
| Master Ensuite | 1 | 0 | Build |
Detailed Scope
Ground Floor Bathroom
1 tasksPre-Construction Planning
GF Bathroom — waterproofing (floor + walls to 1.8m)
UrgentNot Started
Critical. Membrane + primer + AS compliance.
20 sqm @ [price hidden]/sqm. Ardex or Laticrete system, 2-coat membrane + bond breaker + puddle flange. Certified applicator.
CONFIDENCE: 70/100 — Waterproofing rates well-established. Certified applicator rates consistent in Sydney.
QUESTIONS: (1) Membrane system preference (Ardex, Laticrete, Mapei)? (2) Shower niche requiring additional membrane work?
20 sqmGround Floor BathroomPre-Construction Planning
Upstairs Bathroom
1 tasksPre-Construction Planning
FF Bathroom — waterproofing (floor + walls + wet area)
UrgentNot Started
First floor wet area includes shower + bath = larger waterproofing scope.
23 sqm @ [price hidden]/sqm. Ardex or Laticrete system, 2-coat membrane + bond breaker + puddle flange. Certified applicator.
CONFIDENCE: 70/100 — Waterproofing rates well-established. Certified applicator rates consistent in Sydney.
QUESTIONS: (1) Membrane system preference (Ardex, Laticrete, Mapei)? (2) Shower niche requiring additional membrane work?
Scope of works
- 1Prime substrate — Substrate clean, dry, primed per membrane system (Ardex/Laticrete).
- 2Bond breaker to all junctions — Bond breaker + reinforcing to all internal corners and floor/wall junctions.
- 32-coat membrane to compliant heights — Floor 100%, shower walls to 1800mm, other walls 150mm, hob/step per AS 3740.
- 4Seal all penetrations & flange — Waste, flange, tapware penetrations sealed & collared.
- 524h flood test + certificate — Flood test the recess 24h; issue AS 3740 waterproofing certificate.
23 sqmUpstairs BathroomPre-Construction Planning
Master Ensuite
1 tasksConstruction & Fitout
Master Ensuite — waterproofing (floor + walls)
HighNot Started
23 sqm @ [price hidden]/sqm. Ardex or Laticrete system, 2-coat membrane + bond breaker + puddle flange. Certified applicator.
CONFIDENCE: 70/100 — Waterproofing rates well-established. Certified applicator rates consistent in Sydney.
QUESTIONS: (1) Membrane system preference (Ardex, Laticrete, Mapei)? (2) Shower niche requiring additional membrane work?
23 sqmMaster EnsuiteConstruction & Fitout
Sequencing & Dependencies
Tasks that must be coordinated with other trades or completed in a specific order.
GF Bathroom — waterproofing (floor + walls to 1.8m)
Depends on
GF Bathroom — plumbing rough-in (shower, vanity, WC, taps)Ground Floor BathroomFinish → Start
GF Bathroom — electrical rough-in (downlights, exhaust fan, heated towel rail, mirror)Ground Floor BathroomFinish → Start
Blocks
GF Bathroom — wall & floor tilingGround Floor BathroomFinish → Start
FF Bathroom — waterproofing (floor + walls + wet area)
Depends on
FF Bathroom — plumbing rough-in (shower, vanity, WC, bath, taps)Upstairs BathroomFinish → Start
FF Bathroom — electrical rough-in (downlights, exhaust, heated rail, mirror)Upstairs BathroomFinish → Start
Blocks
FF Bathroom — wall & floor tilingUpstairs BathroomFinish → Start
Master Ensuite — waterproofing (floor + walls)
Depends on
Master Ensuite — electrical rough-in (downlights, exhaust, heated rail, mirror)Master EnsuiteFinish → Start
Master Ensuite — plumbing rough-inMaster EnsuiteFinish → Start
Blocks
Master Ensuite — wall & floor tilingMaster EnsuiteFinish → Start
Interested in quoting?